Part 3: Efficiency, system and market · Chapter 9 of 14 · 6 min
Efficiency going forward
H7 and H8: in the sample 48-candle efficiency separated the breakouts (trend minus range +0.31) and the fades (range minus trend +0.22). Going forward the difference on breakouts is +0.09 (random series −0.05, band from −0.56 to +0.36) and on fades −0.02 (band from −0.53 to +0.38): the effect is much smaller and inside the band, and for the fade it has vanished. Trend breakouts make +0.19 and range ones +0.10; fades −0.09 and −0.09. Verdict: inconclusive for both. From the sample to the new data, an effect that was outside the band at a single window did not repeat.
The two hypotheses
Book 17 found that, among the regime measures, only 48-candle efficiency separated results outside the chance band, and only at that window. It called it a «hypothesis to test forward». The two:
- H7: on the breakout rules, the mean R with a trend regime minus the mean R with a range regime (relative regime: 48-candle efficiency above or below the median of the last 500) sits above the chance band. Sample +0.309 (band −0.24/+0.11).
- H8: on the fade rules, the mean R range minus trend sits above the band. Sample +0.224.
The criterion is the basket one: average over rules with at least 5 forward trades in both regimes (192 rules out of 240), compared with 30 random series.
The result
| Sample | Forward | Forward chance band (5th-95th) | Verdict | |
|---|---|---|---|---|
| H7 breakout: trend − range | +0.309 | +0.086 | −0.052 (−0.558/+0.355) | Inconclusive |
| H8 fade: range − trend | +0.224 | −0.020 | −0.061 (−0.533/+0.383) | Inconclusive |
The levels, going forward:
| Mean R over the rules | Trend only | Range only |
|---|---|---|
| Breakout | +0.185 | +0.100 |
| Fade | −0.091 | −0.092 |
Read the chart in words
Daily gold chart with, below, three curves in the forward-test band: the pink one rises to +4.5, the dashed grey one to +3.8 and the blue one to +0.5.
| When | What | Price |
|---|---|---|
| 6 Oct 2026 → 24 Nov 2026 | forward test |
Times in UTC.
How to read it
- The effect shrank. The trend breakout beats the range one by +0.09, against +0.31 in the sample: less than a third.
- The fade lost the effect. In the sample the fade in the range beat the one in the trend by +0.22; going forward the two do the same (−0.09 and −0.09).
- Inside the band. The differences (+0.09 and −0.02) sit inside the bands of −0.56/+0.36 and −0.53/+0.38. The band is more than two and a half times wider than the sample's.
- The breakout's sign held. Trend is better than range, as in the sample. But with so wide a band, even a difference of +0.3 would not have left it.
The verdicts are inconclusive. But there is more useful information than the formal one: an effect that in the sample sat outside the band at a single window (48 candles; at 96 and 168 it sat inside, chapter 9 of book 17) did not repeat visibly in the new data. It is the difference between an effect and a parameter tweak.
What it says about the effect
There are three possible scenarios:
| Scenario | What to expect going forward |
|---|---|
| The effect is true and worth +0.3 | A difference close to +0.3 (but the band reaches +0.36: +0.09 does not rule it out) |
| The effect is a parameter tweak | A difference close to zero, like +0.09 and −0.02 |
| The effect is true but smaller (+0.1) | A difference close to +0.1 |
The new data are compatible with all three: the band (about ±0.45) is wider than the distance between the scenarios. They do not allow a choice. The fade (−0.02) is close to zero as in the «tweak» scenario; the breakout (+0.09) sits between «tweak» and «small but true».
What to do
- Wait for more data before using a regime filter: the sample's effect was not clearly seen.
- Always compare with the sample and with the forward band.
- Treat an effect «at a single window» as suspect until it repeats.
- If you use it, use it to avoid the worst and do not count on the sample's improvement.
- Report differences with their interval, not only the sign.
Procedure in four steps
- Compute the forward difference between regimes over all rules with enough trades.
- Compare with the chance band in the same period.
- Compare with the sample: is the effect equal, reduced or gone?
- Write the compatible scenarios and how much data is needed to pick one.
Exercises
Chapter exercises
1. The efficiency filter gave +0.31 on breakouts in the sample and going forward gives +0.09 with a band from −0.56 to +0.36. What verdict?
2. On the fade the range − trend difference goes from +0.22 to −0.02. What does it say?
3. Why is an effect «at a single window» suspect?
4. The new data are compatible with which scenarios?
Have a question or want to share your exercise?
Post in the community, or join the free signals room on Telegram.
Educational content, not financial advice. Trading involves risk.